Energy meter VM-3P75CT - 3 phase - max 65A/phase
Energie Zähler
Energy meter VM-3P75CT - 3 phase - max 65A/phase
Are you looking for a reliable and precise energy meter for your energy management? Then the VM-3P75CT is just right for you. The VM-3P75CT is a state-of-the-art energy meter that has been specially developed for measuring energy in three-phase systems. It is ideal for use in industrial plants, commercial buildings and larger residential buildings. Whether for the precise monitoring of energy consumption or for the optimization of energy management - with the VM-3P75CT you are well equipped.
The VM-3P75CT energy meter allows you to measure energy consumption up to 65A per phase and delivers precise results. Whether you're an experienced installer or a tech-savvy DIYer, the VM-3P75CT makes installation and operation a breeze. Thanks to its advanced technology and robust construction, the VM-3P75CT is both durable and reliable. This energy meter gives you full control over your energy consumption and allows you to take targeted measures to save energy.
Technical specifications
The VM-3P75CT Energy Meter impresses with its outstanding technical data and versatility. With a maximum load of 65A per phase, it is suitable for a wide range of applications. The Victron VM-3P75CT is designed to accurately measure energy in three-phase systems, making it ideal for commercial and industrial applications.
General description and performance data
- Measuring range: up to 65A per phase -
- Accuracy: Highly precise measurement with minimal deviations -
- Voltage: 3x 230/400V -
- Frequency: 50/60 Hz -
- Interface: RS485 Modbus
Dimensions and physical properties
- Dimensions (H x W x D) 90 x 71 x 59 mm
- Compact design, ideal for use in distribution cabinets
- Robust housing that ensures a long service life
Connection options and compatibility
- Compatible with common monitoring systems
- Easy integration into existing energy management systems
Installation
Some safety precautions must be taken before installing the VM-3P75CT Energy Meter. Make sure that the power is switched off and all necessary tools are ready. Always work according to the operating instructions to avoid errors.
Step-by-step instructions for installation
- Preparation: Switch off the power and check that there is no voltage on the cables.
- Installation: Mount the device in a suitable distribution box.
- Wiring: The VM-3P75CT uses current transformers in the form of clamps to measure the current accurately without having to change the wiring of an existing installation.
- Commissioning: Once the wiring has been completed, the power can be switched on again.
Commissioning
Once the VM-3P75CT Energy Meter has been successfully installed, you can start commissioning. Switch on the device and check the configuration. Make sure that all phases are connected correctly and that the device is working properly.
First steps after installation
- Check the display on your display device
- Carry out a calibration if necessary
- Check the communication with connected systems
Functionality and features
The VM-3P75CT from Victron is characterized by high measurement accuracy and simple operation. The measured values are displayed in the VictronConnect app, a GX device such as the Cerbo GX or Ekrano GX and the VRM portal so that you can record the energy consumption at a glance. The device also has useful additional functions such as load management and alarm functions that help you to optimize energy consumption and detect irregularities at an early stage. The energy meter calculates the RMS power values for each phase and transmits them at a high rate (100ms update rate) via VE.Can or Ethernet, resulting in more accurate measurements of power consumption, grid feed-in and grid feed-in, for example in an ESS system.
Measuring principle and accuracy
The device works on the principle of indirect current measurement and ensures high accuracy even with fluctuating loads.
Connection to monitoring systems
The VM-3P75CT is compatible with a wide range of monitoring software and systems. Thanks to the RS485 Modbus interface, it can be easily integrated into existing systems and enables continuous monitoring of energy consumption.
Configuration of data transmission and communication
- Simple setup of data transmission
- Support of common protocols for energy management systems
Maintenance and troubleshooting
Regular maintenance of the VM-3P75CT Energy Meter is required to ensure a long service life and reliable operation. Regularly check the connections and the functionality of the device.
Frequently occurring faults and how to rectify them
- Check the cabling in the event of error messages
- Ensure that the software settings are correct
With the VM-3P75CT - 3 Phase - max 65A/Phase Energy Meter from Victron, you get a high-quality and reliable device that helps you to monitor and optimize your energy consumption.
At Verkauf-Bochum.de we are happy to provide you with detailed product advice and technical support.