Fronius Primo GEN24 3.0 Plus
SKU 4210140002
by
Fronius
Call
Do you have questions about the product?
Then talk to one of our experts now
+49 (0) 234 - 588 262 88Black Friday Deal --.--.--
1.217,15€
incl. 0% Taxes
Payment methods:
Fronius Primo GEN24 Plus
Inverter for private PV systems with PV Point or Full Backup
Our single-phase hybrid inverter Fronius GEN24 Plus is the ideal heart for private PV systems. The Fronius GEN24 Plus offers an integrated basic emergency power supply with PV Point or even a comprehensive emergency power solution with the option of connecting a battery storage system.
The hybrid inverter Fronius GEN24 Plus enables energy self-sufficiency for electricity, heating, cooling and e-mobility through the use of a battery storage system. This means that Fronius GEN24 Plus with Full Backup* also has an emergency power solution that can supply even large consumers such as heat pumps. Thanks to Multi Flow Technology, the hybrid inverter enables parallel energy flows in the system even in emergency power mode.
* Additional external components for grid switching are required for full backup. Further information can be found in the operating instructions.
Product details
INPUT DATA
| Number of MPP trackers | 2 |
|---|---|
|
Max. PV input power
|
3110 W |
|
Max. Input current (Idc max)
|
22 / 12 A |
|
Max. Short-circuit current module field*
|
36 / 19 A |
|
DC input voltage range (Udcmin - Udcmax)
|
65 - 600 V |
|
Feed-in starting voltage (Udcstart)
|
80 V |
|
Nominal input voltage (Udc,r)
|
400 V |
|
MPP voltage range (Umpp min -Umpp max)
|
190 - 530 V |
| Usable MPP voltage range | 65 - 530 V |
| Number of DC connections | 2+2 |
|
Max. PV generator output (Pdcmax)
|
4.5 kWpeak |
OUTPUT DATA
|
AC rated power (Pac,r)
|
3000 W |
|---|---|
|
Max. Output power (Pac max)
|
3000 VA |
| Max. Mains reference power | 3000 VA |
| Max. AC output current | 19,4 A |
|
Mains connection (Uac,r)
|
1~ NPE 220/230 V |
|
AC voltage range (Umin -Umax)
|
155 - 270 V |
|
Frequency (fr)
|
50 / 60 Hz |
|
Frequency range (fmin - fmax)
|
45 - 65 Hz |
| Distortion factor | <3% @Pnom (230/400VAC 50Hz) |
|
Power factor (cos φac,r)
|
0.8 - 1 ind,/cap, |
| Emergency power | 1~NPE 220 V / 230 V |
|
Nom. AC output current (220VAC)
|
13,6 A |
|
Nom. AC output current (230VAC)
|
13 A |
GENERAL DATA
|
Dimension / Width
|
474 mm |
|---|---|
|
Dimension / height
|
530 mm |
|
Dimension / depth
|
165 mm |
| weight | 15.38 kg |
| Weight incl. packaging | 19 kg |
| Protection class | IP66 |
| Protection class | 1 |
|
Overvoltage category (DC / AC) 1)
|
2 / 3 |
| Night consumption | <10W |
| Inverter concept | transformerless |
| Cooling | Regulated air cooling |
| Mounting | Indoor and outdoor mounting |
| Ambient temperature range | -40°C - +60°C |
| Permissible humidity | 0 - 100 % |
|
Max. Max. altitude above sea level 2)
|
4000m |
| Connection technology DC PV | 4x DC+ and 4x DC- push-in spring terminals 2.5 - 10 mm² |
| DC battery connection technology | 1x BATT+ and 1x BATT- push-in spring terminals 2.5 - 10 mm² |
| Connection technology AC | 3-pole AC push-in spring terminals 2.5 - 10 mm² 3-pole emergency power push-in spring terminals 1.5mm² - 10mm² 2x PE screw terminals 2.5 - 16 mm² and 3x 2.5 - 10mm² |
| Certificates and compliance with standards | IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 and 16150, IEC 62116, IEC 61727 8) |
| Emergency power functions | PV Point, Full Backup 4) |
|
Compatible batteries 6)
|
BYD Battery-Box Premium HVS/HVM & LG FLEX 5) |
| Noise emissions | 42 dB(A) |
| Noise emission class | B |
EFFICIENCY LEVEL
| Max. Efficiency (PV - power grid) | 97,6 % |
|---|---|
| European efficiency (ƞEU) | 96.2 / 97.2 / 96.6 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 5 %Pac,r 3)
|
86.9 / 91.0 / 88.8 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 10 %Pac,r 3)
|
91.8 / 94.6 / 93.2 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 20 %Pac,r 3)
|
95.0 / 96.6 / 96.0 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 25 %Pac,r 3)
|
95.7 / 96.9 / 96.4 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 30 %Pac,r 3)
|
96.1 / 97.1 / 96.7 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 50 %Pac,r 3)
|
96.7 / 97.5 / 97.2 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 75 %Pac,r 3)
|
96.8 / 97.5 / 97.3 (230Vdc / 400Vdc / 530Vdc) |
|
ƞ at 100 %Pac,r 3)
|
96.8 / 97.5 / 97.3 (230Vdc / 400Vdc / 530Vdc) |
| MPP matching efficiency | 99,9 |
PROTECTION DEVICES
| DC insulation measurement | Yes |
|---|---|
| Overload behavior | Operating point shift, power limitation |
| DC disconnector | Yes |
| DC reverse polarity protection | Yes |
INTERFACES
| WLAN / 2x Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
|---|---|
| 6 digital inputs/outputs + 6 digital inputs | Connection to ripple control receiver, energy management |
| Emergency shutdown (WSD) | Yes |
| Data logger and web server | Integrated |
| 2x RS485 | Modbus RTU SunSpec (third-party provider) / Fronius Smart Meter, battery, Fronius Ohmpilot |
OUTPUT DATA PV POINT
| Nom. Output power | 3000 VA |
|---|---|
|
Nom. AC output current (Iac max)
|
13 A |
| Mains connection | 1 ~ NPE 220 V / 230 V |
| Frequency | 50 Hz / 60 Hz |
| Max. Switchover time PV point | 15 s |
| Max. switching time Full Backup | 10 s |
| Frequency in emergency power mode | 53 Hz |
BATTERY CONNECTION
| Number of DC inputs | 1 |
|---|---|
|
Max. Input current (Idc max)
|
22 A |
|
DC input voltage range (Udc min - Udc max)
|
150 V - 455 V 7) |
| Max. Input / output power (depending on connected battery) | 3110 W |
| Max. AC charging power (depending on connected battery) | 3000 W |
| Min. DC input voltage | 150 V |
| Max. DC input voltage | 455 V |

Integrated data communication
We are the first inverter manufacturer to offer a data communication package in which data logging, WLAN, Ethernet, energy management, a web server and numerous interfaces are fully integrated. This means that the inverter is connected to the Internet via network cable or WLAN - without additional cabling - and you have an optimum overview of the operation of the PV system. Connection to third-party components is ensured via interfaces such as Modbus TCP SunSpec, Modbus RTU SunSpec or Fronius Solar API (JSON). In addition, the open interfaces can be operated in parallel with Fronius Solar.web.
Dynamic Peak Manager
The Dynamic Peak Manager is a new type of MPP tracking algorithm that dynamically adapts its behavior when searching for the optimum operating point. The special feature is that the Dynamic Peak Manager regularly checks the entire characteristic curve automatically and thus finds the global maximum power point (GMPP) even in the event of partial shading.
Multi Flow Technology
With Multi Flow Technology, different DC and AC energy flows are possible in parallel. On the one hand, energy from the modules and energy from the battery can be made available to the household at the same time. On the other hand, the energy from the modules can also be fed into the battery and the household grid at the same time. Furthermore, the battery can be charged not only from the DC side, but also from the AC side (for example from existing PV systems or other energy sources such as a wind turbine). This means that the inverter is also suitable for AC-coupled retrofitting. The inverter manages these energy flows in such a way that the highest possible level of self-sufficiency is achieved.
SuperFlex Design
The Fronius SuperFlex Design is an ingenious combination of technical performance features that make designing PV systems particularly flexible and easy for you. The most important performance factors of the SuperFlex Design are Two MPP trackers in combination with the high system voltage and the wide DC input voltage range. Each DC input and therefore each MPP tracker is also able to absorb the entire rated inverter power. Whether different roof orientations, the shading of one or two strings or the use of residual modules: With a Fronius inverter with integrated SuperFlex design, you can cover every relevant design scenario in operational PV planning practice with just one inverter model.
Full Backup
With the Full Backup option, the entire household, i.e. 1-phase and 3-phase devices, can be supplied in the event of an emergency. In addition to the inverter, a battery and a switchover device for safe disconnection from the grid are required for full backup.
PV Point
The integrated basic emergency power supply, a socket supplied with emergency power, ensures that important loads can be operated even in the event of a grid failure.