Battery Management System VE.Bus BMS incl. AC detecor
VE.Bus BMS V2
VE.Bus BMS and VE.Bus BMS V2 are battery management systems (BMS) designed to connect and protect one or more 12.8 V & 25.6 V Lithium Battery Smart batteries (LiFePO4 or LFP) in systems with Victron inverters or inverter/chargers with VE.Bus communication. It monitors and protects the batteries from over- and undervoltage of each cell and also from over- and undertemperatures.
Depending on the status of the battery(s), the BMS:
- Generate a pre-alarm signal to warn of impending cell undervoltage.
- Disable inversion in VE.Bus inverters or inverter/chargers via VE.Bus and disconnect other loads via the "Disconnect Load" terminal in case of cell undervoltage.
- Disable charging in VE.Bus inverters or inverter/chargers via VE.Bus and disable other chargers via the "Disconnect Charging" terminal in case of cell overvoltage, undertemperature or overtemperature.
The "original" VE.Bus BMS is best used in systems without a GX device.
The "next generation" VE.Bus BMS V2 has additional features such as:
- Terminals for remote on/off switching.
- Ability to disable VE.Direct and VE.Can solar chargers from a GX device.
- Possibility to control the VE.Bus inverter/charger from multiple devices, such as the Digital Multi Control, the VE.Bus Smart Dongle and/or a GX device.
- Terminals for auxiliary inputs and outputs that allow a GX device to remain powered in the event of a system shutdown.