Full inverter pool heat pump 20KW, 1-phase

Are you looking for the best way to heat your pool efficiently and cost-effectively? Then we have just the thing for you: The Full-Inverter Pool Heat Pump 20KW, 1-phase. With this technology, you can enjoy warm water at any time of year with minimal energy consumption. Find out more about the benefits and how this innovative heating solution works.

Product description

The Full Inverter pool heat pump with an output of 20KW and single-phase connection is the perfect solution for sustainable and energy-efficient pool heating. The Full Inverter technology allows the heat pump to continuously adjust its output, significantly reducing energy consumption while ensuring a constant water temperature.

Technical specifications:

  • Output: 20KW
  • Power supply: 1-phase
  • Technology: Full inverter
  • Energy efficiency: Up to 50% energy savings compared to conventional pool heaters
  • Noise level: Particularly quiet in operation
  • Environmental friendliness: Use of renewable energy sources

How it works

A full inverter pool heat pump is an advanced pool heating technology that maximizes efficiency and energy savings. Here is a detailed explanation of how it works:

Basic principle of the heat pump

A heat pump works on the principle of heat transfer. It extracts heat energy from the ambient air and transfers it to the pool water. This happens in several steps:

  1. Evaporator: the ambient air is passed through a fan over an evaporator in which a liquid refrigerant circulates. The refrigerant absorbs the heat energy from the air and evaporates.
  2. Compressor: The gaseous refrigerant is then fed into a compressor, which compresses it. Compression causes the temperature of the refrigerant to rise considerably.
  3. Condenser: The hot, gaseous refrigerant then flows through a condenser, where it transfers its heat to the pool water flowing past. The refrigerant cools down and becomes liquid again.
  4. Expansion valve: The liquid refrigerant then flows through an expansion valve, where the pressure and temperature are lowered again before the cycle starts again.

Special features of a full inverter heat pump

Unlike conventional heat pumps, which often operate at a fixed speed, a full inverter heat pump uses technology that can continuously regulate the speed of the compressor and fan. This has several advantages:

  1. High efficiency: the infinitely variable control allows the heat pump to be adapted precisely to the current demand, which reduces energy consumption. When heat demand is low, the pump operates at a low speed and saves energy.
  2. Constant performance: A full inverter heat pump can operate efficiently in different ambient conditions and offers a constant heat output, which is particularly advantageous in changing climatic conditions.
  3. Quiet operation: As the heat pump is not constantly running at full power, operation is significantly quieter. The speed of the compressor and fan can be adjusted to minimize noise.
  4. Longer service life: The more even load on the components reduces wear and tear, resulting in a longer service life for the heat pump.

A full inverter pool heat pump is an energy-efficient and quiet solution for heating swimming pools. It uses the ambient air as a heat source and continuously regulates the speed of the compressor and fan to minimize energy consumption and ensure a constant heating output. The combination of these technologies results in considerable energy savings, quieter operation and a longer service life for the system.

Installation and commissioning

Installation of the 20KW Full Inverter Pool Heat Pump is straightforward and can be carried out by experienced DIY enthusiasts. However, it is advisable to consult a professional to ensure that all safety aspects are taken into account.

Installation instructions:

  1. Select location: The heat pump should be installed in a well-ventilated area close to the pool.
  2. Check connections: Ensure that all electrical connections are correct and securely connected.
  3. Commissioning: After installation, switch on the pool filter and activate the heat pump according to the manufacturer's instructions.

Advantages and benefits

A 20KW, single-phase full inverter pool heat pump offers numerous advantages:

  • Energy efficiency: energy consumption is optimized by continuously adjusting the output.
  • Cost savings: Lower operating costs compared to conventional heating systems.
  • Environmentally friendly: Reduced CO2 emissions and use of renewable energies.
  • Comfort: Constant water temperature for a pleasant bathing experience.

Compared to traditional pool heaters, the Full Inverter technology offers higher efficiency and lower operating costs. The investment in a 20KW Full-Inverter pool heat pump therefore pays for itself quickly.

Energy efficiency and cost savings

Our full inverter pool heat pumps are designed to maximize energy efficiency. Thanks to the advanced inverter technology, you can save up to 50% on energy costs compared to conventional heating systems. This not only means lower electricity bills, but also a smaller environmental footprint.

Care and maintenance

To ensure optimum performance and a long service life for your Full Inverter Pool Heat Pump, regular maintenance is required. Here are some maintenance tips:

  • Clean the filter: Regularly clean the filter to ensure optimal water circulation.
  • Check the appliance: Have a specialist check the heat pump at least once a year.
  • Frost protection: In the winter months, ensure that the heat pump is stored in a frost-proof place.

Frequently asked questions

What exactly is a full inverter pool heat pump?

A full inverter pool heat pump uses inverter technology to continuously adjust the output, making it more efficient and energy-saving.

What advantages does a 20KW full inverter pool heat pump offer for my pool?

You benefit from a constant water temperature, lower energy costs and an environmentally friendly heating system.

Is the installation of a 1-phase Full-Inverter pool heat pump complicated?

The installation is relatively simple, but it is recommended to consult a professional.

How efficient is a 20KW Full-Inverter pool heat pump compared to conventional pool heaters?

Full Inverter pool heat pumps are up to 50% more efficient than conventional heating systems.

Can I use a 20KW, 1-phase Full-Inverter pool heat pump in any pool?

Yes, it is suitable for most pool sizes and types.

What operating costs can I expect with a Full Inverter pool heat pump?

The operating costs are significantly lower than with conventional heating systems, thanks to the high energy efficiency.

How long does it take to heat a pool with a 20KW Full Inverter heat pump?

This depends on the pool size and the initial temperature, but generally faster than conventional heating systems.

Are Full Inverter pool heat pumps environmentally friendly?

Yes, they are very environmentally friendly as they consume less energy and use renewable energy sources.

What maintenance is required for a Full Inverter Pool Heat Pump?

Regular cleaning of the filter and annual inspection by a specialist are recommended.

Can I precisely control the temperature of my pool with a Full Inverter heat pump?

Yes, the inverter technology enables precise control of the water temperature.

Discover the full inverter pool heat pump 20KW, 1-phase at Verkauf-bochum.de now and enjoy your perfectly tempered pool all year round!

FULL-INVERTER POOL heat pump - ABS plastic housing
Model PW040KZXYCH PW050KZXYCH PW060KZXYCH PW080KZXYCH
Recommended pool volume (m3) 40~75 55~100 60~110 70~130
Operating air temperature (℃) -7 ~43
Performance conditions: Air 27°C, water 26°C, humidity 80%
Heating power (kW) 17.00~3.75 20.00~4.00 24.00~4.80 32.5~6.5
Heating capacity (Btu) 57800~13090 68000~13600 81600~16320 110900~22100
Consumed power (kW) 2.62~0.25 3.33~0.27 4.00~0.32 5.42~0.43
COP 6.5~15.0 6.0~14.8 6.0~15.0 6.0~15.0
COP at 50% power 11 11 11,00 11,00
Performance conditions: Air 15°C, water 26°C, humidity 70%.
Heating capacity (kW) 13.0~2.65 15.6~2.85 18.7~3.42 25.4~5.07
Heating capacity (Btu) 44200~9010 53040~9690 63580~11630 86665~17300
Consumed power (kW) 2.58~0.36 3.25~0.40 3.89~0.49 5.29~0.72
COP 5.0~7.4 4.8~7.0 4.8~7.0 4.8~7.0
COP at 50% power 6,5 6,5 6,50 6,50
Performance condition: Air 35℃, water 28℃, humidity 80%
Cooling capacity (kW) 8,6 10,1 11,8 15,6
Sound pressure at 1 m dB(A) 43~52 43~53 44~54 45~57
Sound pressure of 50% of capacity at 1 m dB(A) 44 44 45 49
Sound pressure at 10 m height dB(A) 23~30 24~31 25~32 26~35
Heat exchanger Spiral titanium tube made of PVC
Housing ABS plastic
Coolant R32
Power supply 230V/1 Ph/50Hz 380-400V/3 Ph / 50Hz
Compressor Panasonic
Four-way valve Sanhua
Expansion valve Sanhua
Frequency driver board CHICO
Operating water temperature (℃) *Heating 9 ~40
Operating water temperature (℃) *cooling 9 ~35
Water connection (mm) Φ50
Nominal input current with air 15℃ (A) 11.3~1.6 14.3~1.8 6.9~0.9 9.4~1.3
Recommended water flow rate (m³/h) 6~9 8~10 9~12 12~16
Water pressure loss (max) kPa 12 15 15 25
Net weight/gross weight (kg) 72/86 72/86 80/94 93/108
Size of the product (mm) 1125*416*765 1156*433*905
Packaging size (mm) (plywood box) 1210*450*915 1260*470*1055